Original ArticleIndian Journal of Pharmaceutical Education and ResearchVol. 60 | Issue 3s | 2026 | pp. s1261–s1266Open access
Establishment of a Sensitive and Stability-Indicating RP-HPLC Protocol for Co-Quantification of Empagliflozin and Sitagliptin
- 1*,
- 1,
- 1
- 1 Department of Quality Assurance, Sigma Institute of Pharmacy, Sigma University, Gujarat, INDIA.
Published in Indian Journal of Pharmaceutical Education and Research
Correspondence: Rahil Desai
Department of Quality Assurance, Sigma Institute of Pharmacy, Sigma University, Gujarat, INDIA.
Email: rahildesai1988@gmail.com
Copyright: © 2026 Manuscript Technomedia. This is an open access article.
- Published:
- Jun 2, 2026
- Received:
- Jan 12, 2026
- Accepted:
- May 4, 2026
How to cite
Desai, R., Dalwadi, M., & Upadhyay, U. (2026). Establishment of a Sensitive and Stability-Indicating RP-HPLC Protocol for Co-Quantification of Empagliflozin and Sitagliptin. Indian Journal of Pharmaceutical Education and Research, 60(3s), s1261–s1266. https://doi.org/10.5530/ijper.20262811
Abstract
Aim/Background: To develop a stability-indicating RP-HPLC method for simultaneous quantification of Empagliflozin (EMPA) and Sitagliptin (SITA) in a synthetic mixture for quality control and stability studies. Materials and Methods: Separation used a C18 column with phosphate buffer-methanol-acetonitrile (40:20:40,%v/v/v) at 1.0 mL/min, detected at 224 nm. Validation per ICH Q2(R1) assessed linearity, precision, accuracy, specificity, and robustness. Stress tests included acidic, alkaline, oxidative, thermal, and photolytic conditions. Results: EMPA (2.8 min) and SITA (3.7 min) showed linearity (R² >0.99) over 20-120 µg/mL (EMPA) and 200-1200 µg/mL (SITA), with %RSD < 2% and recovery 99-102%. Detection limits were 1.8 µg/ mL (EMPA) and 4.7 µg/mL (SITA). Stress tests revealed moderate EMPA degradation (acidic/ alkaline) and high SITA degradation (thermal/photolytic), with distinct degradation peaks. This precise, accurate RP-HPLC method is stability-indicating and suitable for routine quality control and stability analysis of EMPA-SITA mixtures per ICH guidelines. Conclusion: The developed RP-HPLC method is precise, accurate, and reliable for simultaneous estimation of EMPA and SITA. Its stability-indicating nature ensures suitability for routine quality control and stability studies of Synthetic Mixture.
Keywords
Subject
Article metadata
| Title | Establishment of a Sensitive and Stability-Indicating RP-HPLC Protocol for Co-Quantification of Empagliflozin and Sitagliptin |
|---|---|
| Authors | Rahil Desai; Mitali Dalwadi; Umesh Upadhyay |
| Affiliations | Department of Quality Assurance, Sigma Institute of Pharmacy, Sigma University, Gujarat, INDIA. |
| Corresponding author | rahildesai1988@gmail.com |
| Journal | Indian Journal of Pharmaceutical Education and Research |
| Volume / Issue | Vol. 60, Issue 3s (2026) |
Also in this issue
- Role of Staple Food Fortification in Combating Micronutrient Deficiencypp. s864–s873
- Advances in Green Bromination: Emerging Eco-Friendly Reagents and Methodologiespp. s874–s881
- Insight into the Recent Advancement of 1,3,4 Oxadiazoles as Potential EGFR and Telomerase Inhibitory for Anticancer Activitypp. s882–s895
- Gold Nanoparticles: Innovative Supramolecular Platforms for Targeted Drug Delivery and Bioorthogonal Catalysispp. s896–s905
- Recent Advances in Phytoconstituent-Based Alpha Glucosidase Inhibitors and Therapeutic Potential for Type 2 Diabetes Mellituspp. s906–s917
Readers Also Viewed
Development and Validation of UV/visible Spectrophotometric Method for Estimation of Piroxicam from Bulk and Formulation
Sandip Mohan Honmane, Kunal Rajaram Yadav, Yuvraj Dilip Dange
Apr 23, 2025
Effects of Artificial Intelligence on Academic Performance of Library and Information Science University Students: A Meta-Analysis (2023-2025)
Kayode Sunday John Dada
Aug 6, 2026
Bridging Innovation and Impact: A Multidisciplinary Approach to Contemporary Research Challenges
Mueen Ahmed KK
Aug 11, 2026