Original ArtcileJournal of Young PharmacistsVol. 6 | Issue 2 | 2014 | pp. 44–49Open access
Evaluation of dried blood spot technique for pharmacokinetic study of hydrochlorothiazide and comparison of human plasma versus dried blood spot
- 1,2*,
- 3
- 1 Department of Pharmacy, Krishna University, Machilipatnam, Andhra Pradesh, INDIA.
- 2 Accutest Research Laboratories India Private Limited, Khairane MIDC, Navi Mumbai, Maharashtra, INDIA.
- 3 Bapatla College of Pharmacy, Bapatla, Guntur, Andhra Pradesh, INDIA.
Published in Journal of Young Pharmacists
Correspondence: P Pavan Kumar
Department of Pharmacy, Krishna University, Machilipatnam, Andhra Pradesh, INDIA.; Accutest Research Laboratories India Private Limited, Khairane MIDC, Navi Mumbai, Maharashtra, INDIA.
Email: prathipatipavan@gmail.com
Copyright: © 2014 Manuscript Technomedia. This is an open access article.
- Published:
- May 21, 2014
- DOI:
- 10.5530/jyp.2014.2.7
How to cite
Kumar, P. P., & Murthy, T. (2014). Evaluation of dried blood spot technique for pharmacokinetic study of hydrochlorothiazide and comparison of human plasma versus dried blood spot. Journal of Young Pharmacists, 6(2), 44–49. https://doi.org/10.5530/jyp.2014.2.7
Abstract
Background: The dried blood spot (DBS) technique is a convenient alternative sample collection method to venipuncture. The use of DBS was fi rst widely introduced in the 1960’s by Dr. Guthrie to measure levels of phenylalanine in newborns for the diagnosis of phenylketonuria. The scientifi c community has recently expressed interest in applying the DBS technique for quantifi cation of drugs in biological fl uids. Materials and Methods: Reversed phase high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays for the determination of hydrochlorothiazide (HCTZ) in human plasma and DBS samples were developed and validated. Furthermore, clinical samples collected from human volunteers as a part of pharmacokinetic (PK) study and PK data from plasma were compared against DBS. Results: The range of reliable response in plasma and DBS was 2-200 ng/mL with a correlation coeffi cient ≥0.997. Inter-day accuracy was always within 85-115%, and inter-day precision for plasma and DBS were <15%. Conclusions: Comparison of HCTZ PK data in DBS and plasma yielded good correlation, indicating that DBS can be used as a plasma alternative for PK analyses in vivo.
Keywords
Subject
Article metadata
| Title | Evaluation of dried blood spot technique for pharmacokinetic study of hydrochlorothiazide and comparison of human plasma versus dried blood spot |
|---|---|
| Authors | P Pavan Kumar; TEGK Murthy |
| Affiliations | Department of Pharmacy, Krishna University, Machilipatnam, Andhra Pradesh, INDIA.; Accutest Research Laboratories India Private Limited, Khairane MIDC, Navi Mumbai, Maharashtra, INDIA.; Bapatla College of Pharmacy, Bapatla, Guntur, Andhra Pradesh, INDIA. |
| Corresponding author | prathipatipavan@gmail.com |
| Journal | Journal of Young Pharmacists |
| Volume / Issue | Vol. 6, Issue 2 (2014) |
Also in this issue
- Seven-star pharmacist concept by World Health Organizationpp. 1–3
- High productivity pharmaceutical organizations in India: A study of their performance during 2008-12pp. 4–13
- Atypical antipsychotic drugs in India: A scientometric study during 1998-2013pp. 14–24
- Riociguat, a guanylate cyclase stimulator for the treatment of pulmonary hypertensionpp. 25–28
- Risk assessment for COPD using chronic CAT questionnaire and Vitalograph COPD-6 screening devicepp. 29–34
Readers Also Viewed
Development and Validation of UV/visible Spectrophotometric Method for Estimation of Piroxicam from Bulk and Formulation
Sandip Mohan Honmane, Kunal Rajaram Yadav, Yuvraj Dilip Dange
Apr 23, 2025
Effects of Artificial Intelligence on Academic Performance of Library and Information Science University Students: A Meta-Analysis (2023-2025)
Kayode Sunday John Dada
Aug 6, 2026
Bridging Innovation and Impact: A Multidisciplinary Approach to Contemporary Research Challenges
Mueen Ahmed KK
Aug 11, 2026