Case ReportJournal of Young PharmacistsVol. 9 | Issue 1 | 2016 | pp. 137–139Open access
Proton Pump Inhibitor-induced Hypersensitivity Reaction: A Case Report
- 1*,
- 1,
- 1,
- 1,
- 1,
- 1
- 1 Department of Pharmacology, R. G. Kar Medical College, Khudiram Bose Sarani, Kolkata-700004, West Bengal, INDIA.
Published in Journal of Young Pharmacists
Correspondence: Anjan Adhikari
Department of Pharmacology, R. G. Kar Medical College, Khudiram Bose Sarani, Kolkata-700004, West Bengal, INDIA.
Email: dradhikarianjankolkata@gmail.com
Copyright: © 2016 Manuscript Technomedia. This is an open access article.
- Published:
- Nov 11, 2016
- Received:
- Sep 22, 2016
- Accepted:
- Oct 1, 2016
How to cite
Adhikari, A., Indu, R., Ray, M., Bhattacharya, S., Biswas, R., & Das, A. K. (2016). Proton Pump Inhibitor-induced Hypersensitivity Reaction: A Case Report. Journal of Young Pharmacists, 9(1), 137–139. https://doi.org/: 10.5530/jyp.2017.9.28
Abstract
Introduction: Drug induced allergy or hypersensitivity reaction is of great clinical significance in therapeutics. Various factors may contribute like age, genetic composition, disease of the patients and the types of drugs used. Such reactions increases the patient’s suffering and lowers the therapeutic efficacy of any drug. Therefore, it is essential to collect data and inves tigate important drug reactions for safe therapy. Presentation of Case: A 27-years old female patient, with a history of drug allergy to ranitidine, experienced severe anaphylactic shock immediately after cesarean delivery. Post-operative medications include Ceftriaxone, Metronidazole, Tramadol, Metoclopramide and Pantoprazole. With intravenous injections of Adrenaline, Hydrocortisone, Dexamethasone, Atropine, Promethazine and intubation, she slowly recovered after three days and was discharged. Conclusion: Past history of the patient suggested a rare case of drug allergy to ranitidine. Therefore, instead of ranitidine, pantoprazole was used for this patient. Clinicians suspected this anaphylactic reaction may be induced by drug. However, the drug responsible for this reaction was not detected clearly but Pantoprazole may be a possibility. Though allergy due to H2 receptor antagonists and proton-pump inhibitors are rare but may cause fatal consequences. Thus proper investigation of this case may help in designing the treatment schedule in an effective way, in future.
Keywords
Subject
Article metadata
| Title | Proton Pump Inhibitor-induced Hypersensitivity Reaction: A Case Report |
|---|---|
| Authors | Anjan Adhikari; Rania Indu; Moumita Ray; Sangita Bhattacharya; Rahul Biswas; Anup Kumar Das |
| Affiliations | Department of Pharmacology, R. G. Kar Medical College, Khudiram Bose Sarani, Kolkata-700004, West Bengal, INDIA. |
| Corresponding author | dradhikarianjankolkata@gmail.com |
| Journal | Journal of Young Pharmacists |
| Volume / Issue | Vol. 9, Issue 1 (2016) |
Also in this issue
- Let’s not ignore when the patient snores in clinic: an alarming call for oral health care professionalspp. 1–2
- Switching Drugs from Rx to OTC status – A Regulatory Perspectivepp. 3–7
- Perioceutics in the management of Periodontal Diseasepp. 8–13
- Autoimmune Disorders–Immunopathogenesis and Potential Therapiespp. 14–22
- A Computational Approach to Design Potential Antiviral RNA for 3’UTR Post Transcriptional Gene Silencing of Different Strains of Zika Viruspp. 23–30
Readers Also Viewed
Development and Validation of UV/visible Spectrophotometric Method for Estimation of Piroxicam from Bulk and Formulation
Sandip Mohan Honmane, Kunal Rajaram Yadav, Yuvraj Dilip Dange
Apr 23, 2025
Effects of Artificial Intelligence on Academic Performance of Library and Information Science University Students: A Meta-Analysis (2023-2025)
Kayode Sunday John Dada
Aug 6, 2026
Bridging Innovation and Impact: A Multidisciplinary Approach to Contemporary Research Challenges
Mueen Ahmed KK
Aug 11, 2026