Original ArtcileJournal of Young PharmacistsVol. 9 | Issue 2 | 2017 | pp. 177–182Open access
Application of Experimental Design to Develop a Robust RP-TLC/ Densitometry Method for Quantification of Phthalates in Person al Care Products
- 1,
- 1*
- 1 Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kancheepuram District–603 203, Tamilnadu, INDIA.
Published in Journal of Young Pharmacists
Correspondence: Karunanidhi Santhana Lakshmi
Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kancheepuram District–603 203, Tamilnadu, INDIA.
Email: kavitha0208@gmail.com
Copyright: © 2017 Manuscript Technomedia. This is an open access article.
- Published:
- Apr 23, 2017
- Received:
- Nov 26, 2016
- Accepted:
- Feb 14, 2017
How to cite
Kavitha, J., & Lakshmi, K. S. (2017). Application of Experimental Design to Develop a Robust RP-TLC/ Densitometry Method for Quantification of Phthalates in Person al Care Products. Journal of Young Pharmacists, 9(2), 177–182. https://doi.org/10.5530/jyp.2017.9.35
Abstract
Objective: A rapid, simple and economic RP-TLC/Densitometry method for the simultaneous quantification of Phthalates, namely Dimethyl Phthalate (DMP), Diethyl Phthalate (DEP) and Di-n-butyl Phthalate (DBP) in Personal care products was developed and validated. Central Composite design (CCD) with three factors and one response is employed to study the robustness of the developed method. Method: The best chromatographic separation was achieved using Methanol: Toluene: Hexane: GAA (6:2:1:1 v/v/v/v) as the solvent system at 275 nm. The developed method was examined for validation parameters like linearity, specificity, precision, accuracy and robustness. Results: The method was found linear over a wide range of 2.0–200 ng/band with a regression coefficient of 0.999, 0.998 and 0.998 for DMP, DEP and DBP respectively. Limit of detection (LOD) and Limit of Quantification (LOQ) was found to be 0.035 and 0.106 ng/band, 0.072 and 0.218 ng/band 0.076 and 0.232 ng/band for DMP, DEP and DBP respectively. The %RSD for Precision studies for DMP, DEP and DBP were found to be 1.63 – 1.82, 1.13 – 1.52 and 1.58-1.60 respectively. Accuracy, ascertained by employing % Recovery was calculated and found between 97-103% w/w. CCD generated and carried out proves the method devel oped was robust. Conclusion: All the validation parameters were reported to be within the acceptance limit. The proposed and developed RP-TLC/ Densitometry method can be applied for routine analysis of DMP, DEP and DBP in Personal care products and can also be extended to the analysis in pharmaceuticals and food products.
Keywords
Subject
Article metadata
| Title | Application of Experimental Design to Develop a Robust RP-TLC/ Densitometry Method for Quantification of Phthalates in Person al Care Products |
|---|---|
| Authors | Jayaseelan Kavitha; Karunanidhi Santhana Lakshmi |
| Affiliations | Department of Pharmaceutical Analysis, SRM College of Pharmacy, SRM University, Kattankulathur, Kancheepuram District–603 203, Tamilnadu, INDIA. |
| Corresponding author | kavitha0208@gmail.com |
| Journal | Journal of Young Pharmacists |
| Volume / Issue | Vol. 9, Issue 2 (2017) |
Also in this issue
- Comparison of Adverse Effects of Newer Atypical Antipsychotics: An Evidence Based Reviewpp. 140–144
- Highly Cited Publications Output by India in Clinical Pharmacology during 2000-14: A Scientometric Assessmentpp. 145–157
- Design, Synthesis and Characterization of Benzothiazole Analogues as Promising Pharmacological Agentspp. 158–161
- 3D QSAR Studies on Some 5-(1H-Indol-5-yl)-1, 3, 4-Thiadiazol-2 Amines as Potential PIM-1 Inhibitorspp. 162–167
- In-Silico Screening of Flavonoids Targeted for Death Receptors in Cancer by Using Hex Molecular Dockingpp. 168