Short CommunicationJournal of Young PharmacistsVol. 6 | Issue 1 | 2014 | pp. 39–41Open access
Biosensor for uric acid determination based on the combination of polypyrrole and poly (allylamine) films
- 1*,
- 1,
- 1,
- 1
- 1 Faculty of Pharmacy, Universitas Padjadjaran, INDONESIA.
- 2 Department of Chemistry, Faculty of Mathematics and Natural Sciences, Jl Raya Bandung Sumedang KM 21, 5 Jatinangor, Jawa Barat, INDONESIA.
Published in Journal of Young Pharmacists
Correspondence: Aliya Nur Hasanah
Faculty of Pharmacy, Universitas Padjadjaran, INDONESIA.
Email: aliya_nh@yahoo.com
Copyright: © 2014 Manuscript Technomedia. This is an open access article.
- Published:
- Apr 3, 2014
- DOI:
- 10.5530/jyp.2014.1.7
How to cite
Hasanah, A. N., Wathoni, N., Refiani, A. I., & Wahyuni, Y. (2014). Biosensor for uric acid determination based on the combination of polypyrrole and poly (allylamine) films. Journal of Young Pharmacists, 6(1), 39–41. https://doi.org/10.5530/jyp.2014.1.7
Abstract
Aim and Background: The use of polypyrrole and poly(allylamine) as a matrix of biosensor has been done separately, but the combination of this two has never existed. The purpose of this research is to produce a selective biosensor using combination of polypyrrole (PPy) and poly(allylamine) (PAA) as a polymer for the immobilization of the uricase enzyme, which is used to detect uric acid level in the blood. Materials and Methods: Biosensor manufacturing process began with the electropolimerization of pyrrole on platinum wire then immobilization r turicase enzyme (UOx) with glutaraldehyde as cross-linker, After that, UOx and PAA were deposited via layer-by-layer sequential deposition up to 10 UOx layers to prepare amperometric sensors for uric acid. Biosensor proved to have a linear relationship between the current response and the increase of analyte concentrations, with a correlation coeffi cient (r) = 0.992. Results and Conclusion: Presence of interferences had a little effect on uric acid analysis i.e. 1.39% glucose and1.65% ascorbic acid. The sensors could be used up to 32 times. In the stability test, 13.4% of the initial amperometric response decreased at day 33rd. The results showed that combination of PPy and PAA can be used as a matrix for uric acid biosensor.
Keywords
Subject
Article metadata
| Title | Biosensor for uric acid determination based on the combination of polypyrrole and poly (allylamine) films |
|---|---|
| Authors | Aliya Nur Hasanah; Nasrul Wathoni; Aldilla Indah Refiani; Yeni Wahyuni |
| Affiliations | Faculty of Pharmacy, Universitas Padjadjaran, INDONESIA.; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Jl Raya Bandung Sumedang KM 21, 5 Jatinangor, Jawa Barat, INDONESIA. |
| Corresponding author | aliya_nh@yahoo.com |
| Journal | Journal of Young Pharmacists |
| Volume / Issue | Vol. 6, Issue 1 (2014) |
Also in this issue
- Experimental design approach to optimize stability indicating liquid chromatography method for the determination of naftopidil in its bulk and tablet dosage formpp. 1–7
- Investigation of various practical techniques to enhance dissolution of ezetimibe from oral tablets: A comparative studypp. 8–14
- Formulation and development of multiparticulates dosage form of propranolol hydrochloridepp. 15–21
- Cytochrome P450 genetic variants and hypertension risk in South Indian populationpp. 22–26
- Assessment of learning domains to improve student’s learning in higher educationpp. 27–33
Readers Also Viewed
Effect of the Fractions of Coccinia grandis on Ethanol- Induced Cerebral Oxidative Stress in Rats
M. Umamaheswari, T. K. Chatterjee
Jan 1, 2009
Phytochemical Screening and Antioxidant Activity Evaluation of Selected Philippine Fruit Peels and Pulps
Mildred Dagcuta Pates, Angelo Mark Po Walag, Romeo M. Del Rosario
Aug 17, 2026
Impact of Artificial Intelligence Assisted Drug Therapy Optimization on Drug Related Problems Amongst Older Adult Patients: A Systematic Review
Jehath Syed, Christy Thomas, Bavneet Kaur
Oct 23, 2026