Pharmaceutical AnalysisJournal of Young PharmacistsVol. 1 | Issue 3 | 2009 | pp. 259–263Open access
Development and Validation of TLC-Densitometry Method for Simultaneous Determination of Telmisartan and Amlodipine Besylate in Bulk and Tablets
- 1*,
- 2,
- 1,
- 1
- 1 Shree Dhanvantary Pharmacy College, KIM, INDIA.
- 2 Smt. B.N.B. Swaminarayan Pharmacy College, Salvav, INDIA.
Published in Journal of Young Pharmacists
Correspondence: Vekariya NR
Shree Dhanvantary Pharmacy College, KIM, INDIA.
Email: nitin.vekariya@gmail.com
Copyright: © 2009 Manuscript Technomedia. This is an open access article.
- Published:
- Aug 16, 2009
How to cite
NR, V., MB, P., GF, P., & RB, D. (2009). Development and Validation of TLC-Densitometry Method for Simultaneous Determination of Telmisartan and Amlodipine Besylate in Bulk and Tablets. Journal of Young Pharmacists, 1(3), 259–263. https://doi.org/10.4103/0975-1483.57076
Abstract
A rapid, simple, and selective high performance thin layer chromatographic method was developed and validated for simultaneous estimation of telmisartan and amlodipine besylate in pharmaceutical dosage forms. The method employed TLC aluminium plates precoated with silica gel 60F-254 as the stationary phase. The solvent system comprised: tetrahydrofuran: dichloroethane: methanol: ammonia solution (6.0:2.0:1.0:0.4 v/v). This system was found to give compact spots for both telmisartan (Rf value of 0.22 ± 0.02) and amlodipine besylate (Rf value of 0.45 ± 0.02). Spectrodensitometric scanning-integration was performed at a wavelength of 326 nm. The polynomial regression data for the calibration plots showed good linear relationship with r2 = 0.9993 in the concentration range of 1,2007,200 ng for telmisartan and 4001,400 ng for amlodipine besylate with r2 = 0.9996. The method was validated for precision, accuracy, ruggedness, and recovery. The minimum detectable amounts were found to be 149.41 ng and 53.07 ng for telmisartan and amlodipine besylate, respectively. The limits of quantitation were found to be 452.78 ng for telmisartan and 160.83 ng for amlodipine besylate. Statistical analysis proves that the method is reproducible and selective for the simultaneous estimation of telmisartan and amlodipine besylate.
Keywords
Subject
Article metadata
| Title | Development and Validation of TLC-Densitometry Method for Simultaneous Determination of Telmisartan and Amlodipine Besylate in Bulk and Tablets |
|---|---|
| Authors | Vekariya NR; Patel MB; Patel GF; Dholakiya RB |
| Affiliations | Shree Dhanvantary Pharmacy College, KIM, INDIA.; Smt. B.N.B. Swaminarayan Pharmacy College, Salvav, INDIA. |
| Corresponding author | nitin.vekariya@gmail.com |
| Journal | Journal of Young Pharmacists |
| Volume / Issue | Vol. 1, Issue 3 (2009) |
Also in this issue
- Systematic Reviews in Pharmacy – A vision forwardpp. 191
- Sir Ram Nath Chopra: A Profilepp. 192–194
- Design and in vitro Evaluation of Mucoadhesive Microcapsules of Pioglitazonepp. 195–198
- Preparation and Characterization of Chitosan-based Superporous Hydrogel Compositepp. 199–204
- Development and Characterization of Niosomal Drug Delivery of Gliclazidepp. 205–209
Readers Also Viewed
Development and Validation of UV/visible Spectrophotometric Method for Estimation of Piroxicam from Bulk and Formulation
Sandip Mohan Honmane, Kunal Rajaram Yadav, Yuvraj Dilip Dange
Apr 23, 2025
Effects of Artificial Intelligence on Academic Performance of Library and Information Science University Students: A Meta-Analysis (2023-2025)
Kayode Sunday John Dada
Aug 6, 2026
Bridging Innovation and Impact: A Multidisciplinary Approach to Contemporary Research Challenges
Mueen Ahmed KK
Aug 11, 2026